M3000-60003 Non-Invasive Blood Pressure (NIBP) Pump NIBP Module For IntelliVue MP2/X2 /MP20 /MP30/ MP50/ MP70

商品の詳細:
ブランド名: IntelliVue
モデル番号: MP2/X2
お支払配送条件:
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: 通常パッケージ
支払条件: T/T、ウェスタンユニオン、ペイパル
供給の能力: 60
  • 詳細情報
  • 製品の説明

詳細情報

カテゴリ: 血中酸素モジュール 交換部品: メーカー純正部品
支払い方法: PayPal、銀行振込 パッケージ: 通常の標準パッケージ
サービス: 修理サービス 部品: パラメータモジュール
修理範囲: ハードウェアとソフトウェア モデル: MPシリーズ
使用: 患者モニター 支払い: T/T、ウェスタンユニオン、ペイパル
所要時間: 3-7 営業日 保証: 修理後90日
リードタイム: 1~3営業日以内

製品の説明

M3000-60003 Non-Invasive Blood Pressure (NIBP) Pump NIBP Module For IntelliVue MP2/X2 /MP20 /MP30/ MP50/ MP70
M3000-60003 is a Non-Invasive Blood Pressure (NIBP) pump assembly designed as an internal replacement component for specific  patient monitors and monitoring modules. It is a field-replaceable unit (FRU) responsible for the mechanical inflation and deflation of the blood pressure cuff during automated measurements.
Product Specifications
Part Number M3000-60003
Alternative OEM Number 453564748091
Product Type NIBP Pump Assembly (internal component)
Condition Typically available as refurbished, tested, or OEM surplus
Core Exchange Often required (old unit returned for refurbishment)
Device Compatibility

The M3000-60003 NIBP pump is compatible with specific patient monitors and Multi-Measurement Modules (MMS). Compatibility is primarily determined by serial number ranges.

Confirmed Compatible Devices:
Device Family Specific Models / Requirements
IntelliVue MP2 (M8102A), X2 (M8002A), MP5
MMS Modules M3001A MMS Module with serial numbers starting with DE6 or higher, specifically DE9
Additional Devices M3002A Module
Critical Compatibility Note: The M3000-60003 is the correct replacement pump for M3001A MMS modules with serial numbers beginning with DE6 and higher, including the DE9 series. Earlier serial number ranges require different pump assemblies (M3000-60001 or M3000-60002).
Technical Function

The NIBP module is the pneumatic heart of the blood pressure measurement system. It performs the following functions:

  • Cuff Inflation: The internal pump generates the necessary pressure to inflate the blood pressure cuff wrapped around the patient's arm or leg.
  • Controlled Deflation: Precision valves manage the gradual release of cuff pressure according to the oscillometric measurement principle.
  • Pressure Transduction: The assembly contains sensors that detect pressure oscillations in the artery, which are then converted into electrical signals for processing by the monitor's main system.
Service and Replacement
Installation Context

The M3000-60003 is an internal component that resides within the M3001A MMS module or the monitor chassis. Replacement requires disassembly of the device. For the MP5 monitor, replacement involves a multi-step process including:

  • Removing the power supply
  • Removing system interface and recorder boards
  • Accessing the NBP pump cage
When Replacement is Needed

Common failure indicators that suggest NIBP pump replacement include:

  • "NIBP Hardware Error" messages
  • "Pump Timeout" or "Leak Test Failed" alarms
  • Failure to inflate or maintain cuff pressure
  • Inaccurate or erratic blood pressure readings despite proper cuff placement
  • Unusual noises from the pump (grinding, continuous running)
Post-Installation Requirements

After replacing the M3000-60003, the following steps are typically required:

  • NIBP Calibration: A full static pressure calibration must be performed to ensure clinical accuracy
  • Leak Testing: Verification of pneumatic system integrity
  • Service Mode Access: Calibration procedures are performed through the monitor's internal Service Mode (requires specific access key sequence or password)
M3000-60003  Non-Invasive Blood Pressure (NIBP) Pump  NIBP Module For IntelliVue MP2/X2 /MP20 /MP30/ MP50/ MP70 0
Summary: The M3000-60003 is a specialized NIBP pump assembly designed for the IntelliVue MP2/X2 portable monitors and M3001A MMS modules with serial numbers DE6 and higher. As an internal replacement part, it restores automated non-invasive blood pressure measurement functionality when the original pump fails. Proper installation requires technical service access, and calibration is mandatory after replacement to ensure measurement accuracy.