logo
Guangzhou YIGU Medical Equipment Service Co.,Ltd

IntelliVue MX40 SPO2 Board wearable portable patient monitor Spo2 Board for 1.4 GHZ/2.4GHZ version

商品の詳細:
ブランド名: IntelliVue
モデル番号: MX40
お支払配送条件:
最小注文数量: 1
価格: 交渉可能
パッケージの詳細: 通常パッケージ
受渡し時間: 1~2日
支払条件: Paypal、T/T、ウェスタン・ユニオン
供給の能力: 40
  • 詳細情報
  • 製品の説明

詳細情報

配送: 受け取りと配送のオプションが利用可能 一致: 患者モニター
強さ: オリジナル 品質保証: 修理後にテストおよび校正済み
サービスの種類: 販売法 モデル番号: MX40
品質: 良い 支払い: Paypal、T/T、ウェスタン・ユニオン
料金: 交渉

製品の説明

IntelliVue MX40 SPO2 Board Wearable Portable Patient Monitor
SpO2 Board for 1.4 GHz/2.4 GHz Version
Product Overview
The IntelliVue MX40 is a wearable, portable patient monitor designed to provide continuous monitoring for ambulatory patients in hospital environments. Its primary purpose is to allow patients freedom of movement while remaining under clinical supervision, functioning primarily as a traditional telemetry device.
Key Features and Design
  • Compact Design: Small, lightweight, and wearable design enables patient mobility without disconnecting from monitoring systems
  • User Interface: Color touchscreen allows clinicians to view patient data (ECG and SpO2), manage alarm settings, and review alarm history
  • Display Management: "Display off" mode conserves battery life and provides patient comfort during nighttime
  • Connectivity: Wireless connection to IntelliVue Information Center (central nursing station) for primary monitoring and alarm functions
  • Versatile Power: Choice between rechargeable lithium-ion battery or standard AA batteries for clinical flexibility and patient transport needs
Clinical Applications
  • Designed for adult and pediatric patients in hospital settings
  • Suitable for intra-hospital transport monitoring
  • Indicated for monitoring, recording, and generating alarms for multiple physiological parameters
  • Supports progressive care for patients with varying levels of acuity
Safety and Performance Notices
Important Safety Information
Several safety notices and recalls have been issued for the MX40. Users should be aware of the following historical issues (addressed by software updates and corrective actions):
  • Alarm and Battery Issues: Previous recalls involved risks of device failing to sound audible alarms due to software issues, including increased power consumption leading to unexpected battery drain and missing software options for arrhythmia detection
  • Standby Mode: When in "standby mode," physiological monitoring and alarming are completely stopped. The device must not be left in this state unintentionally

私達と連絡を取ってください

あなたのメッセージを入れて下さい

あなたはこれらに入るかもしれない